Ashland Ashland is committed to a zero-incident culture
Return to Composite Polymers
1 3 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

     Found 16 Chemical Environments beginning with "R"

Chemical
Environment
Concen-
tration %
Temperature (oF) For Resin Type
High Performance Epoxy
Vinyl Ester Resins
Epoxy Vinyl Ester
Resins
  Fume Service
HETRON
942/35
HETRON
980/35
HETRON
FR998/35
HETRON
970/35
HETRON
922, FR992
HETRON
980
HETRON
197-3
HETRON
800
AROPOL
7241, 7334
HETRON
92/99P
R-2 Solutions Sat'd. - - - - - -, - - 180 - -,- -,-
Radiochemical Hoods Gloves Boxes - - - - - -, - - - - -,- 90,-
RAYLENETM  50 - - - - -, - - 150 - -,- -,-
Rayon Spin Bath  - - - - 140 150, 150 150 180 - -,- 170,-
Rayon Spin Bath, Fumes  - - - - - -, - - LS200 LS200 -,- NR,-
Rayon Spinning Fumes  - - - - 140 -, - - 140 - -,- 140,100
Recovery Boiler, Blow Down Acetic, Sulfuric, Sulfurous, and Formic Acids. Acetone - - - - - NR, NR - 210 - NR,NR NR,-
Recovery Boiler, Kraft Type No contact evaporation, trace of Sulfur Dioxide, 12-14% Carbon Dioxide, 19% by volume moisture, 37 fps - - - - - NR, NR - 340 - NR,NR -,-
Recovery Boiler, Stack Gases  - - - - - NR, NR NR 300 - NR,NR -,-
Red Liquor Ammonium Bisulfite Based - - 180 - 180 150, 150 165 150 - -,- -,-
Reformer Charge  - - - - - -, - - - - 90,- -,-
Resorcinol  100 - - - - -, - - - 250 -,- -,-
Rhodium Plating, Phosphate  - - - - - -, - - 120 - -,- -,-
RICHAMIDE CDATM  100 - - - - -, - - 120 - -,- -,-
RICHONATE 1850TM  100 - - - - -, - - 120 - -,- -,-
RJ-4 Fuel  100 - 80 - - 80, 80 80 80 - 80,80 80,-


If you cannot find your chemical environment in this guide, or if you have any questions regarding the information contained in this guide, please email at Hetron@ashland.com or CPDSpecialtyTS@ashland.com.